A Technology Minded Company

  • Technical Support
  • |
  • Contact Us
  • |
  • +91 22 67969798
  • 219, Hill View Ind. Est., Amrut Nagar Rd., Ghatkopar (W), Mumbai - 400086.
  • search

  • Overview
  • Specification

CPM: Continuous Particulate Measurement

The SEMTECH CPM is a real-time PM measurement system that meets the requirements of both US EPA CFR 40 part 1065 and EU ECE Reg. 49.

Features

  • 1065 and EU ECE Reg. 49 compliant: The SEMTECH CPM meets the preliminary requirements for US EPA Part 1065 and EU ECE Reg. 49 compliance requirements for in-use testing, when integrated with SEMTECH MPS and PFS.
  • PM Mass or Number: The module may be calibrated to accurately measure either particle mass or number.
  • Flow-through transducer design: The CPM is designed to extract a diluted aerosol sample from either a third party diluter, the MPS or a CVS sampling system. This results in improved performance (humidity effects, pulsation effects, etc.) and greatly reduces service intervals.
  • Protection from contamination while not in operation: The CPM module is configured with a zero air solenoid to enable real-time zeroing as well as providing a stand-by feature.
  • Power supply monitoring: Power can be either 12 VDC, 110 VAC or 220 VAC, with both current and voltage monitoring.
  • Weatherproof construction: All components meet IP54 (NEMA standards).
  • Shock Resistance: The mechanical design has been optimized for resistance to shock and vibration, ensuring data acquisition in the most harsh environments.
  • Design Details: Over a decade of experience in in-use emissions testing has gone into the design details of the SEMTECH ECOSTAR system, including:

    • EMI protection, including gaskets, filters
    • Stress relief for pneumatic connections
    • Channels for cable management
    • Standard Swagelok™ bulkhead connectors
    • Rugged Deutsch connectors for power and auxiliary connectors
    • Handles that lock to other SEMTECH ECOSTAR modules for stable system integration

Click Here to download PDF


Sensors’ SEMTECH CPM utilizes an ion mobility technique (based on the Pegasor® PPS-M) whereby clean air is ionized and mixed with the sample, charging the particles. As charged particles exit the sensor (Faraday cup) their charge is measured with a sensitive electrometer. Accordingly, the SEMTECH CPM is a real-time PM measurement system that can be configured to measure either PM Mass or PM Number concentrations. The module can be employed as a standalone analyzer, or integrated with the SEMTECH MPS and PFS to provide a complete SEMTECH PM measurement solution for both real-world or laboratory applications.


Regulations: 1065 and reg. 49 compliant
Measurement technique: Ion Mobility
Minimum size:
Maximum size:
From 23nm (dependent on selected trap voltage)
2.5μm (dependent on measured particle size distribution)
Concentration: From 1μg to 250mg/m3
Response time: <0.3s
Maximum data rate: 10Hz (high speed internal averaging)
Operating temperature: 0 to 50°C
Operating humidity: 0 to 90% RH
Communications: Ethernet, USB
Dimensions: 44.5cm x 43cm x 19cm (17.5” x 17” x 7.5”)
Weight: 20kg (44lbs)
Power: 12 VDC, 110/220 VAC
Power consumption: < 250W